Title: The impact of envelope airtightness on energy performance of buildings
Original Title: Utjecaj zrakopropusnosti ovojnice na energijsko svojstvo zgrada
Authors: Sanjin Gumbarević, Bojan Milovanović
DOI: https://doi.org/10.5592/CO/PhDSym.2019.01
First page: 9 Last page: 21
Publish date print/online: 9/10/2019
Abstract: The impact of airtightness of buildings on energy performance is not adequately presented if we observe its true impact on the building energy demand. The Republic of Croatia requires a certain level of building airtightness, which should be controlled before technical inspection of the building. However, in many cases this airtightness is not controlled at all. Parametric analysis of energy models of two buildings in EnergyPlus shows the impact of airtightness on the annual heating energy demand, where this impact is more significant for well-insulated buildings.
Keywords: airtightness, infiltration, Building Energy Modelling, EnergyPlus, Building Performance Simulation
Sažetak: Utjecaj zrakopropusnosti ovojnice na energijsko svojstvo zgrade nije dovoljno istican i ne pridaje mu se važnost koju svakako ima. Hrvatski propisi zahtijevaju određenu razinu zrakopropusnosti koja bi se trebala kontrolirati ispitivanjem prije tehničkog pregleda zgrade, ali se ispitivanje u velikom broju slučajeva ne provodi. Parametarskom analizom energetskih modela dviju zgrada u programskom paketu EnergyPlus prikazan je utjecaj zrakopropusnosti ovojnice na potrebnu godišnju energiju za grijanje, gdje taj utjecaj posebno dolazi do izražaja u zgradama koje su kvalitetno toplinski izolirane.
Ključne riječi: zrakopropusnost, infiltracija, modeliranje energije zgrade, EnergyPlus, simulacija ponašanja zgrade